III. International Science and Innovation Congress ( INSI 2022 ) , Ankara, Türkiye, 9 - 12 Haziran 2022, ss.105-110
Abstract
In this study, the effects of antenna radiation on the equipment under test (EUT) were investigated by
the RS103 test defined in the MIL-STD-461G standard. For this purpose, Electric Field Generator
and Biconical Antenna radiating between 30MHz – 100MHz were used. It has been observed that
different currents occurred on the EUT cable under the same electric field. In addition, in order to
examine the effect of different currents, the same test setup has been organized with a digital
thermometer. It is revealed that EUTs did not show similar behavior when subjected to different
antennas providing the same conditions.
Keywords: Electromagnetic compatibility, electric field generator, biconical antenna, RS103.